Seaward PrimeTest 250
$14.72
$23.55
Seaward PrimeTest 250 PT250 - Comprehensive handheld manual PAT tester Home > Products > Discontinued Products > Seaward PrimeTest 250 Seaward PrimeTest 250 PAT Testers PrimeTest 250 Comprehensive handheld manual PAT tester Seaward’s lightweight, portable Primetest 250 PAT tester is unique in its range of safety tests. The PrimeTest 250 will perform all of the tests required by the IEE Code of Practice, including RCD trip, protective conductor current and touch current where required. The unit also includes a 250V DC insulation test suitable for testing sensitive electrical appliances and surge protected leads. The PrimeTest 250 is ideal for ensuring that all workplace electrical equipment does not pose a danger to users -including three-phase machinery*. As a result, 3-phase industrial plant and equipment used in factories, workshops, schools and colleges can all be tested safely and effectively. The unique range of tests incorporated in this lightweight and highly versatile instrument means that most workplace appliances can be tested using long life battery power. However, when protective conductor current or touch current measurements are required, simply connecting a mains supply will automatically select the correct test sequence. The Primetest 250 is designed for ease of use and carries out all electrical safety tests against pre-set limits with measured test results and clear PASS/FAIL indication on a large display. The PrimeTest 250 is an easy-to-use tester which is ideal for those who need to test a wide range of electrical equipment. *For 3 phase and RCD testing, accessories are required. Features: Clear LCD Display All portable appliance tests listed in the IET Code of Practice Tests class I and II equipment including IT and business equipment Extension and IEC lead tests Socket polarity check RCD tests on 30mA 3 Phase differential leakage current* Voltage AC and DC *Requires additional adaptors Specifications Earth continuity0.01 Ω - 19.99 Ω, 200mA minimum into 2Ω Pass valuePass value 0.2 Ω Insulation resistance0.01 MΩ - 19.99 MΩ, 250/500VDC @1mA nominal Pass value1 MΩ Class I, 2 MΩ Class II Equivalent leakage0.15mA to 9.99mA, 40V nominal AC Pass value0.75mA CL I / 0.25mA CL II IEC lead test5V DC nominal IEC checksChecks Live/Neutral for c/c, s/c, and crossed Protective conductor current (earth leakage)0.15mA to 9.99mA, Supply voltage, max current 13A Pass value0.75 mA/3.50mA user selectable with 0.75mA as default Touch current0.10mA to 5.00mA, Supply voltage, max current 13A Pass value0.25mA RCD trip time10mA / 30mA rms, 0ms to 500ms @ 0 & 180 Degrees auto switched Pass value200ms 3 phase differential leakage current *Requires 3 phase adaptor accessory0.10mA to 9.99mA, 3 phase supply voltage Pass value3.5mA Power socket check225 - 254V AC max current 13A Line potential phase to earth Line potential phase to neutral Line potential neutral to earth Power supply6 x AA batteries / 225-245V AC for powered tests Dimensions260 x 100 x 55 mm Weight800 g Downloads Spec Sheet Trade Price: £Discontinued - See PT250 all prices exclude VAT Related Products Seaward Seaward PrimeTest 250 Seaward PrimeTest 50 PowerCheck 1557 369A910 Seaward Apollo 500 (380A928) PAT Tester Seaward PrimeTest 100
Discontinued Products